La logique impliquée est beaucoup plus complexe.
À l'heure actuelle, la logique est simple:
if AC Mode and it's too hot, turn on AC, else turn off AC
if Furnace mode and its too cold turn on furnace, else turn off furnace
Mais la détermination du moment de basculer entre les modes de chauffage et de refroidissement est beaucoup plus complexe - sinon la climatisation se déclencherait et il ferait trop froid, donc le four se mettrait en marche, le rendant trop chaud, et un cycle commencerait qui ne jamais finir.
La logique doit donc être plus comme:
if the average ambient temperature has remained below a certain threshhold
for a given period of time
and the air conditioner hasn't been on in quite a while, change to furnace mode
but if average ambient temperature has remained ABOVE a certain threshhold
for a given period of time
and the furnace hasn't been on in quite a while, change to a/c,
then if we're in furnace mode and it's cold, turn on the furnace,
but if we're in a/c mode, and it's hot, turn on the a/c.
Les circuits impliqués sont beaucoup plus complexes, donc le prix est plus élevé et la part de marché sera évidemment plus petite.